Features
PLC connections, plant logic and data for whoever needs it: all in one executable, configured from the browser.
Channels to the field
Each PLC with its native protocol. All channels are included in the licence.
| Channel | What it connects | Notes |
|---|---|---|
| Siemens S7 | S7-300, S7-400, ET200, S7-1200/1500 with classic access, WinAC, virtual PLCs | DBs, bit memory (M), inputs, outputs, timers, counters |
| Siemens S7-1200/1500, optimised DBs | S7-1200 and S7-1500 with optimised DBs and PUT/GET disabled | Symbolic access: DBs are browsed by name, no change to the PLC program |
| Rockwell EtherNet/IP | ControlLogix, CompactLogix and PLC5 | Browser of controller and program tags, UDT members as tags; PLC5 with data file addresses (N7:0) |
| Modbus TCP / RTU over TCP | Drives, energy meters, instruments, serial gateways | RTU over TCP to serial gateways; registers, coils, bits; signed integers, floats and 64-bit counters in both word orders, as used by power meters and protection relays |
| Mitsubishi MELSEC (SLMP) | FX5U and iQ-F, Q, L, iQ-R from the built-in Ethernet port | Over TCP or UDP; devices read in blocks; X and Y in octal as in the program |
| OPC UA client | Third-party OPC UA servers: PLCs with a built-in server, other gateways, SCADA | Discovery, node browser, encrypted and authenticated channel |
| WinCC Unified | WinCC Unified runtime via OpenPipe | With the WinCC Unified bridge installed on the runtime PC |
| MQTT | A broker seen as a PLC: topics become tags, tags are published | Included in every level |
| Nodaris OT | The PLCs of another Nodaris OT, in another department or site | Find the remote node on the network, create the key from the wizard, tick the PLCs. Pushed values, forwarded writes |
Data for whoever uses it
The same tag, read once from the PLC, reaches every system that asks for it.
OPC UA server
Publishes the tags of all channels in a single OPC UA tree. Encrypted endpoints, certificate that can be regenerated from the browser, users with passwords and lockout after repeated failed logins, mDNS announcement on the network and statistics for every connected client. The OPC UA server and the virtual S7 PLC are enabled and disabled from their own page, without restarting the service.
- REST API with OpenAPI documentation and a test page served by the server itself, even without Internet; tokens and three user levels
- Data source for Grafana: history, current values and events
- Publishing to an MQTT broker
Several departments, one point of view
Each department or site has its own Nodaris OT close to the PLCs. A central Nodaris OT brings them together as gateways.
Department gateway
The department's Nodaris OT keeps the connections with the PLCs on its network. The central one imports it as a gateway: the PLCs appear under their gateway, in the Gateway section of the Connections and services page, and are used like all the others.
Guided pairing
The New gateway wizard finds the Nodaris OT nodes available on the network, creates the access key with the remote administrator's two-factor authentication and lets you tick the PLCs to import.
Light traffic
The gateway sends only the values that change; writes start from the central node and reach the PLC through the gateway. An imported PLC can be taken out of service without touching the others.
From the browser, without stopping the plant
Configuration and maintenance are done from the pages, with the server in service.
- Connections, tags, automatic copy, scripts and history are edited from the pages. Before a file is activated the server checks it; if the reload fails, it goes back to the previous configuration by itself
- One-click configuration backup, optionally encrypted, and restore from the same page
- Service keys for Grafana, SCADA and other programs: each with the lowest level it needs, revocable at any time
- Cluster page with the state of both nodes and the role switchover
- Windows setup that installs the service; signed package for Linux, which keeps the way back to the previous version at every update
- Pages in Italian and English, chosen by whoever opens them, usable also on the 1024x768 monitors of shop-floor PCs
Plant logic, without extra software
The small automations that usually end up on a forgotten PC under a desk.
Automatic copies between PLCs
One line copies a tag from one PLC to another, of any brand and protocol, on change or on a cycle. The write goes out immediately, without waiting for the read cycle. The page shows, row by row, whether each copy is working.
Scripts and databases
Pascal, Basic or JavaScript scripts, on a cycle or when a tag changes, written and tested in the browser. They read and write tags, call HTTP services and work with SQL Server, PostgreSQL, MySQL, Firebird and SQLite: recipes, production counters, local history. Web and SQL requests can run in parallel and the answer arrives when ready: a script that waits does not hold up the others.
- Internal tags: server memory seen as a PLC, optionally retentive: the value survives a restart and follows the standby node
- Virtual S7 PLC for testing and for clients that cannot reach the real PLC
Seeing the plant
Web pages served by the server itself, in Italian and English, with light and dark themes.
Dashboards for department monitors
The values that matter, large and readable from a distance: temperatures, machine status, parts per shift, trend charts. Built in the browser from a template; each monitor gets a link with its own key, tracked and revocable. Besides values and charts: gauges and bars, tables, status lights, active alarms, shift or monthly consumption, pie breakdowns, a shift run bar, text and logos.
The Map page
The graph of connections by plant area, with animated data flows: it explains the plant to newcomers and reveals dependencies before anyone touches a PLC.
Built-in historian
Records the chosen series with no database needed; without the Database option it keeps 60 days, with the option for years, locally or on an external database (PostgreSQL with TimescaleDB) that Grafana reads directly. For energy, water and gas meters it works out shift, daily or monthly consumption itself, even when the meter rolls over. Swinging-door compression keeps only the points needed to redraw the curve within tolerance. Series are organised in groups and searched by name.
Reports from Excel templates
You design the template once, in Excel or directly in the browser with the template editor. Nodaris OT fills it with tags, history and consumption figures and produces the report as PDF, Excel or HTML: on a schedule, from the Reports page or from a script.
Always on
For plants where the data server cannot stop.
Active/passive cluster
Two Linux IPCs with a replicated volume and one virtual address for the clients. The standby node keeps the configuration loaded and, when the active node fails, becomes active in less than a second. The standby node's pages show values and connections as the active node sees them; fencing is handled by the plant PLC.
Measured failover
Data visible again to the clients 29 seconds after the loss of the active node: almost all of it is the time to detect the failure, promoting the standby takes less than a second. Measured on a production plant with 82 PLC connections. Dashboards stay on during the switchover.
One licence file
A single licence file for both nodes, with the HA passive node option (from Edge, included in Enterprise). Updates one node at a time, without stopping the plant.
Security and compliance
The evidence plant operators need for NIS2, and documentation prepared in line with the Cyber Resilience Act.
- Hash-chained audit log and syslog forwarding to the SIEM
- Two-factor authentication and Active Directory domain users
- Native HTTPS, encrypted OPC UA, configurable allowed networks
- Signed packages and binaries, integrity checks of pages and configuration
- E-mail notifications of important events and a daily report
- IEC 62443-4-2 self-assessment, CycloneDX SBOM and coordinated vulnerability disclosure policy
- Security fixes for 5 years from delivery, even without active maintenance; the source code of the LGPL libraries comes with every delivery
Which level is right for you?
Six levels, from Gateway for a single machine to Enterprise for the whole site: the level depends on how many sources and external tags you connect, and the server counts them itself. Tell us about your plant: we will prepare a quote.